Overzicht specificaties
-
Measured variables
CH4, CO, CO2, Corg, HCl, HF, H2O, NH3, NO, NO2, N2O, O2, SO2, NOx, C3H8, C2H6
-
Ambient temperature range
+5 °C ... +35 °C
With cooling device:+5 °C ... +50 °C -
Process temperature
≤ +1,300 °C
Toepassingsgebied
The FTIR measurement principle enables the simultaneous acquisition of more than 12 measuring components. The MCS100FT FTIR analyzer system with its heated measuring cell made of corrosion-resistant material also enables monitoring of hydrogen fluoride limits as required by legislation. With its reliable measurement technology, easy operation, and low maintenance requirements, the MCS100FT provides a hassle-free solution concept that offers unequaled opportunities.
Emission monitoring in waste incineration plants
Reliable HF limit value monitoring
Monitoring of gaseous emissions in cement or power plants
Device properties:
Small suitability-tested HF measuring range: 0 ... 3 mg/m³
Automatic spectrum adjustment via AutoVAL for reliable measured values
Suitability-tested according to EN15267
Remote control and diagnosis via SOPAS ET software
Automatic adjustment of the analyzer
Automatic backwashing and filter cleaning of the extraction unit
Voordelen
Reliable HF limit value monitoring
Just one analyzer for over 12 measuring components
Easy integration into the customer network environment
Long 6-month maintenance interval for many measuring components
Suitability-tested measurement of greenhouse gases such as N2O, CH4 and CO2
Low maintenance effort
Xpert selectie
-
Gespecialiseerde producten
- Ontworpen voor veeleisende applicaties
Technische topkwaliteit
Eenvoud
Variabel
-
Eenvoudige producten
- Gemakkelijk te selecteren, installeren en gebruiken
Technische topkwaliteit
Eenvoud
-
Standaardproducten
- Betrouwbaar, robuust en onderhoudsarm
Technische topkwaliteit
Eenvoud
-
Gespecialiseerde producten
- Ontworpen voor veeleisende applicaties
Technische topkwaliteit
Eenvoud
Variabel
FLEX selectie | Technische topkwaliteit | Eenvoud |
---|---|---|
Fundamental selectie Voldoe aan uw basismeetvoorwaarden |
Technische topkwaliteit
|
Eenvoud
|
Lean selectie Beheers eenvoudig uw belangrijkste processen |
Technische topkwaliteit
|
Eenvoud
|
Extended selectie Optimaliseer uw processen met innovatieve technologieën |
Technische topkwaliteit
|
Eenvoud
|
Xpert selectie Beheers uw meest uitdagende applicaties |
Technische topkwaliteit
|
Eenvoud
Variabel |
-
-
Bedieningshandleiding (BA)
MCS100FT
FTIR Multicomponent Analysis System for Continuous Flue Gas Monitoring
EN NL 01/01/2025Taal:
Engels
Versie:
01/01/2025
Bestandsgrootte:
3.6 MB
Bestandsnaam:
8029896_1K96_OI_MCS100FT_en_V2-2_2023-11_EHS.pdf
-
-
-
Industriële oplossing (SO)
Broad range of solutions for waste-to-energy plants
Endress+Hauser offers ideal automation and safety solutions for collection, sorting and recycling of waste.
Taal:
Engels
Versie:
01/01/2025
Bestandsgrootte:
2.4 MB
Bestandsnaam:
8030416_SO_Waste_en_V1-0_2025.01_EHS.pdf
-
-
-
Competentiebrochure (CP)
Emission Monitoring Solutions – broad instrument portfolio and longstanding experience
An overview brochure about emission monitoring, their measuring
principles and technologies, global requirements and services, a
selection guide and the measuring devices at a glanceTaal:
Engels
Versie:
01/01/2025
Bestandsgrootte:
4.5 MB
Bestandsnaam:
8029975_CP_Emission_Monitoring_Solutions_en_V3-0_2025.01_EHS.pdf
-
-
-
Innovatie (IN)
MCS100FT FTIR analyzer system
With one FTIR analyzer system for providing complete and continuous emission monitoring
Taal:
Engels
Versie:
01/01/2025
Bestandsgrootte:
2.6 MB
Bestandsnaam:
8029954_IN_MCS100FT_en_V4-0_2025.01_EHS.pdf
-
-
-
Verificatie DTM
MCS100FT SDD file
SOPAS device description file for MCS100FT
Taal:
Language neutral
Versie:
18/12/2014
Bestandsgrootte:
18 MB
Bestandsnaam:
MCS100FT SDD file
-
-
-
Verificatie DTM
MCS100FT, FID100FT SDD file
SOPAS device description file for MCS100FT, FID100FT
Taal:
Language neutral
Versie:
25/11/2015
Bestandsgrootte:
458 KB
Bestandsnaam:
MCS100FT, FID100FT SDD file
-