Overzicht specificaties
-
Max. meetfout
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
-
Measuring range
0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d)
-
Medium temperature range
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194°F) -
Max. process pressure
PN 40, Class 300, 20K
-
Wetted materials
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +160 °F)
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)
Toepassingsgebied
Thanks to its international approvals (e.g. for drinking water), Promag W serves a wide variety of applications. It is available as both compact or remote version. With its straightforward hard- and software design, Promag W 10 simplifies every step in its life cycle from engineering to servicing at usual Endress+Hauser quality. Heartbeat Technology enables measurement reliability and compliant verification.
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity.
Suitable for elementary measurement tasks such as raw water intake.
Device properties
International drinking water approvals
Degree of protection IP68 (Type 6P enclosure)
System integration with HART, Modbus RS485
Flexible operation with app and optional display
Voordelen
Reliable measurement at constant accuracy with 0 x DN inlet run without pressure loss
Flexible engineering – sensor with fixed or lap-joint process connections
Application fitness – EN ISO 12944 corrosion protection for underground or underwater installation
Improved plant availability – sensor compliant with industry-specific requirements
Optimum usability – operation with mobile devices and SmartBlue app or display with touch screen
Simple, time-saving commissioning – guided parameterization in advance and in the field
Integrated verification – Heartbeat Technology
Video's
Lean selectie
-
Standaardproducten
- Betrouwbaar, robuust en onderhoudsarm
Technische topkwaliteit
Eenvoud
-
Eenvoudige producten
- Gemakkelijk te selecteren, installeren en gebruiken
Technische topkwaliteit
Eenvoud
-
Standaardproducten
- Betrouwbaar, robuust en onderhoudsarm
Technische topkwaliteit
Eenvoud
-
Gespecialiseerde producten
- Ontworpen voor veeleisende applicaties
Technische topkwaliteit
Eenvoud
Variabel
FLEX selectie | Technische topkwaliteit | Eenvoud |
---|---|---|
Fundamental selectie Voldoe aan uw basismeetvoorwaarden |
Technische topkwaliteit
|
Eenvoud
|
Lean selectie Beheers eenvoudig uw belangrijkste processen |
Technische topkwaliteit
|
Eenvoud
|
Extended selectie Optimaliseer uw processen met innovatieve technologieën |
Technische topkwaliteit
|
Eenvoud
|
Xpert selectie Beheers uw meest uitdagende applicaties |
Technische topkwaliteit
|
Eenvoud
Variabel |
Voorganger
-
-
Technische informatie (TI)
Proline Promag W 10
Engelse versie - 10/2022
Electromagnetic flowmeter
EN NL 03/10/202201/07/2021Taal:
Engels
Versie:
03/10/2022
Bestandsgrootte:
4 MB
Bestandsnaam:
TI01580DEN_0222-00.pdf
-
-
-
Bedieningshandleiding (BA)
Proline Promag W 10
Engelse versie - 10/2022
Electromagnetic flowmeter HART
EN NL 03/10/202201/07/2021Taal:
Engels
Versie:
03/10/2022
Bestandsgrootte:
4.7 MB
Bestandsnaam:
BA02070DEN_0222-00.pdf
-
-
-
Technische informatie (TI)
Proline Promag W 10
Electromagnetic flowmeter
EN NL 03/10/202201/07/2021Taal:
Engels
Versie:
03/10/2022
Bestandsgrootte:
4 MB
Bestandsnaam:
TI01580DEN_0222-00.pdf
-
-
-
Bedieningshandleiding (BA)
Proline Promag W 10
Electromagnetic flowmeter
HARTEN NL 03/10/202201/07/2021Taal:
Engels
Versie:
03/10/2022
Bestandsgrootte:
4.7 MB
Bestandsnaam:
BA02070DEN_0222-00.pdf
-
-
-
Bedieningshandleiding (BA)
Proline Promag W 10
Electromagnetic flowmeter
Modbus RS485EN NL 03/10/202201/07/2021Taal:
Engels
Versie:
03/10/2022
Bestandsgrootte:
4.1 MB
Bestandsnaam:
BA02073DEN_0222-00.pdf
-
-
-
Instrumentparameters (GP)
Proline Promag 10
Electromagnetic flowmeter
HARTEN NL 03/10/202201/07/2021Taal:
Engels
Versie:
03/10/2022
Bestandsgrootte:
1.5 MB
Bestandsnaam:
GP01157DEN_0222-00.pdf
-
-
-
Instrumentparameters (GP)
Proline Promag 10
Electromagnetic flowmeter
Modbus RS485EN NL 03/10/202201/07/2021Taal:
Engels
Versie:
03/10/2022
Bestandsgrootte:
1.6 MB
Bestandsnaam:
GP01158DEN_0222-00.pdf
-
-
-
Beknopte instructie (KA)
Flowmeter Proline 10
HART transmitter
met elektromagnetische sensorEN NL 03/10/202201/07/2021Taal:
Nederlands
Versie:
03/10/2022
Bestandsgrootte:
3.2 MB
Bestandsnaam:
KA01497DNL_0322-00.pdf
-
-
-
Beknopte instructie (KA)
Flowmeter Proline 10
Modbus RS485 transmitter
met elektromagnetische sensorEN NL 03/10/202201/08/202101/07/2021Taal:
Nederlands
Versie:
03/10/2022
Bestandsgrootte:
2.6 MB
Bestandsnaam:
KA01499DNL_0322-00.pdf
-
-
-
Beknopte instructie (KA)
Flowmeter Proline PromagW
Elektromagnetische sensor
EN NL 01/11/202401/08/202215/01/202201/09/202103/05/2021Taal:
Nederlands
Versie:
01/08/2022
Bestandsgrootte:
1.1 MB
Bestandsnaam:
KA01266DNL_1122-00.pdf
-
-
-
Montage-instructies (EA)
Replacing the Sensor
Promag 10
EN NL 03/10/202204/04/202220/08/2021Taal:
Engels
Versie:
03/10/2022
Bestandsgrootte:
942.5 KB
Bestandsnaam:
EA01353DA2_0322-00.pdf
-
-
-
Montage-instructies (EA)
EA Replacing the transmitter, non Ex/Zone 2/Div. 2/Ex db/Zone 1/Div. 1
Proline 10
EN NL 12/06/202415/03/202303/10/202204/04/202220/08/2021Taal:
Engels
Versie:
12/06/2024
Bestandsgrootte:
1.4 MB
Bestandsnaam: