Overzicht specificaties
-
Process temperature
-40°C ... 150°C
(-40°F ... 300°F) -
Process pressure / max. overpressure limit
Vacuum ... 25 bar
(Vacuum ... 360 psi) -
Min. density of medium
200 g/l
Toepassingsgebied
Soliphant FTM20 is a point level switch for applications with fine-grained or coarse-grained, non-fluidized bulk solids. The various designs means the device has a wide range of applications. Certificates are also available for use in dust and hazardous areas.
Point level switch for fine grained solids
Process connections: Threads
Temperature: -40 to +150°C (-40 to +300°F)
Pressure: -1 to +25bar (-14.5 to +360psi)
Sensor material: 316L
International explosion protection certificates
Voordelen
No calibration required, easy commissioning (plug and play)
Measurement not affected by build-up or external vibration
No mechanically moved parts, free of maintenance
Sensor material 316L, abrasion resistant even with building materials
Plastic housing with cover with sight glass, switch status visible from outside;
also aluminium housing availableNot affected by flow noises
Available with explosion protection certificates
Video's
Fundamental selectie
-
Eenvoudige producten
- Gemakkelijk te selecteren, installeren en gebruiken
Technische topkwaliteit
Eenvoud
-
Eenvoudige producten
- Gemakkelijk te selecteren, installeren en gebruiken
Technische topkwaliteit
Eenvoud
-
Standaardproducten
- Betrouwbaar, robuust en onderhoudsarm
Technische topkwaliteit
Eenvoud
-
Gespecialiseerde producten
- Ontworpen voor veeleisende applicaties
Technische topkwaliteit
Eenvoud
Variabel
FLEX selectie | Technische topkwaliteit | Eenvoud |
---|---|---|
Fundamental selectie Voldoe aan uw basismeetvoorwaarden |
Technische topkwaliteit
|
Eenvoud
|
Lean selectie Beheers eenvoudig uw belangrijkste processen |
Technische topkwaliteit
|
Eenvoud
|
Extended selectie Optimaliseer uw processen met innovatieve technologieën |
Technische topkwaliteit
|
Eenvoud
|
Xpert selectie Beheers uw meest uitdagende applicaties |
Technische topkwaliteit
|
Eenvoud
Variabel |
Voorganger
-
-
Technische informatie (TI)
Soliphant T FTM20, FTM21 Technical Information
Engelse versie - 08/2018
Robust point level switch for bulk solids, also for dust incendive hazard areas
EN NL 31/08/201808/01/201813/07/201708/12/201609/04/2008Taal:
Engels
Versie:
31/08/2018
Bestandsgrootte:
2.1 MB
Bestandsnaam:
TI00389FEN_1618.pdf
-
-
-
Beknopte instructie (KA)
Exchange of electronic insert on Soliphant T FTM20, FTM21
Engelse versie - 05/2021
Exchange of electronic insert on Soliphant T FTM20, FTM21
EN NL 19/05/2021Taal:
Engels
Versie:
19/05/2021
Bestandsgrootte:
177.3 KB
Bestandsnaam:
KA00621FA2_0909.pdf
-
-
-
Technische informatie (TI)
Soliphant T FTM20, FTM21 Technical Information
Robust point level switch for bulk solids,
also for dust incendive hazard areasEN NL 31/08/201808/01/201813/07/201708/12/201609/04/2008Taal:
Engels
Versie:
31/08/2018
Bestandsgrootte:
2.1 MB
Bestandsnaam:
TI00389FEN_1618.pdf
-
-
-
Beknopte instructie (KA)
Exchange of electronic insert on Soliphant T FTM20, FTM21
Exchange of electronic insert on Soliphant T FTM20, FTM21
EN NL 19/05/2021Taal:
Engels
Versie:
19/05/2021
Bestandsgrootte:
177.3 KB
Bestandsnaam:
KA00621FA2_0909.pdf
-
-
-
Beknopte instructie (KA)
Operating Instructions Soliphant T FTM20, FTM21
Robust point level switch for bulk solids,
also for dust incendive hazard areasEN NL 08/01/201813/07/201708/12/201630/09/2004Taal:
Engels
Versie:
08/01/2018
Bestandsgrootte:
1.2 MB
Bestandsnaam:
KA00227FA6_1518.pdf
-
-
-
Ex-veiligheidsinstructie (XA)
Soliphant T FTM20, FTM21
ATEX, IECEx:
Ex ta/tb IIIC Da/DbEN NL 02/08/202113/04/201614/03/201301/11/201101/08/2004Taal:
Nederlands
Versie:
02/08/2021
Bestandsgrootte:
407.9 KB
Bestandsnaam:
XA00300FNL_1621.pdf
-
-
-
Ex-veiligheidsinstructie (XA)
XA Soliphant T FTM20, FTM21
Ex ta/tb IIIC T135 °C Da/Db
EN NL 06/02/202411/12/202005/10/2017Taal:
Engels
Versie:
06/02/2024
Bestandsgrootte:
401 KB
Bestandsnaam:
XA01681FEN_0323-00.pdf
-
-
-
Ex-veiligheidsinstructie (XA)
Soliphant T FTM20, FTM21
Ex ta IIIC T170°C Da X and Ex tc IIIC T170°C Dc X
EN NL 25/05/202030/07/2018Taal:
Engels
Versie:
25/05/2020
Bestandsgrootte:
115.4 KB
Bestandsnaam:
XA01420FEN_0220.pdf
-
-
-
Ex-veiligheidsinstructie (XA)
Soliphant T FTM20, FTM21
Ex ta/tb IIIC T135°C Da/Db
EN NL 04/08/202222/01/201816/04/201301/02/2008Taal:
Engels
Versie:
04/08/2022
Bestandsgrootte:
505.7 KB
Bestandsnaam:
XA00434FEN_1522-00.pdf
-
-
-
Ex-veiligheidsinstructie (XA)
Safety Instructions Soliphant T FTM20, FTM21
Ex ta/tc IIIC T170°C Da/Db
IECEx KEM07.0043EN NL 14/03/201301/10/200701/04/2007Taal:
Engels
Versie:
14/03/2013
Bestandsgrootte:
134.2 KB
Bestandsnaam:
XA00424FA3_1313.pdf
-
-
-
Ex-veiligheidsinstructie (XA)
Soliphant T FTM20, FTM21
II 1/2 D Ex ta/tb IIIC Da/Db
Taal:
Engels
Versie:
16/09/2021
Bestandsgrootte:
396 KB
Bestandsnaam:
XA02703FEN_0121-00.pdf
-
-
-
Activiteitsgebieden (FA)
Level measurement
Product overview for applications in liquids and bulk solids
Taal:
Engels
Versie:
14/10/2022
Bestandsgrootte:
10.5 MB
Bestandsnaam:
FA00001F00EN2522.pdf
-