©Endress+Hauser
iTHERM TT412 Imperial Hygienic Thermowell with QuickNeck
©Endress+Hauser
iTHERM TT412 Imperial Hygienic Thermowell with Tri-Clamp process connection
©Endress+Hauser
iTHERM TT412 Imperial Hygienic Thermowell with QuickNeck and weld-in adapter
©Endress+Hauser
TT412 elbow thermowell and iTHERM QuickNeck
©Endress+Hauser
Half-section view of the TT412 elbow thermowell, with the thermowell projecting straight into one side of the pipe bend
Overzicht specificaties
Max. process pressure (static)
Maximum standard immersion length
Toepassingsgebied
Best applicable for use in hygienic or aseptic pipes and containers or tanks even with very small immersion lengths. It meets increased protection requirements of the temperature sensor regarding physical and chemical effects. Ideally suited to all measuring points that require regular re-calibration by simply replacing the insert in closed processes.
Specially designed for use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries
Pressure range up to 40 bar (580 psi)
For increased protection requirements of the temperature sensor regarding physical and chemical effects
For use in pipes and containers or tanks
Ideally suited to all measuring points that require regular recalibration by simply replacing the insert in closed processes
Voordelen
iTHERM QuickNeck – cost and time savings thanks to simple, tool-free recalibration of the insert used
All common hygienic process connections
International certification: hygiene standards as per 3-A, EHEDG, ASME BPE, FDA, TSE Certificate of Suitability
Fast response time owing to reduced tips with thin walls
State of the art Tee and Elbow elements, without welds and dead legs and with best in class hygienic design
Extended selectie
High-end producten
Functioneel en uiterst doelmatig
Technische topkwaliteit
Eenvoud
©Endress+Hauser
Eenvoudige producten
Gemakkelijk te selecteren, installeren en gebruiken
Technische topkwaliteit
Eenvoud
Standaardproducten
Betrouwbaar, robuust en onderhoudsarm
Technische topkwaliteit
Eenvoud
High-end producten
Functioneel en uiterst doelmatig
Technische topkwaliteit
Eenvoud
Technische topkwaliteit
Eenvoud
FLEX selectie
Technische topkwaliteit
Eenvoud
Fundamental selectie
Voldoe aan uw basismeetvoorwaarden
Technische topkwaliteit
Eenvoud
Lean selectie
Beheers eenvoudig uw belangrijkste processen
Technische topkwaliteit
Eenvoud
Extended selectie
Optimaliseer uw processen met innovatieve technologieën
Technische topkwaliteit
Eenvoud
Xpert selectie
Beheers uw meest uitdagende applicaties
Technische topkwaliteit
Eenvoud
Loading alternative products
Succesverhalen
Zelfkalibrerende thermometers in hygiënische processen
In deze white paper wordt verklaard, hoe zelfkalibrerende thermometers kunnen worden gebruikt in hygiënische procestechniek. Zowel theorie als praktijk komen aan bod met toepassingsvoorbeelden. Meer informatie!
Lees het hele verhaal
Medische autoclaven
Met nieuwe sensortechnologie worden herkalibraties geautomatiseerd om risico's bij batchsterilisatie te beperken. Meer informatie!
Lees het hele verhaal
Characteristic / Application
imperial style hygienic/aseptic design (3-A®, EHEDG, ASME BPE, FDA) hygienic process connections iTHERM QuickNeck for easy and cost saving recalibration
Maximum standard immersion length
Process connection
weld in adaptor clamp connections acc. to ISO2852 thread acc. to ISO 228 for liquiphant adaptor APV Inline Varivent Tee and elbow thermowells DIN11865
Thermowell root diameter
1/4" (6,35 mm) 3/8" (9,525 mm) 1/2" (12,7mm)
Wetted part finishing (Ra)
< 30 μinch (0,76 μm) < 15 µinch(0,38 μm) < 15 μinch (0,38 µm) electropolished
Temperature range
-200...650 °C (-328...1.202 °F)
Max. process pressure (static)
Max. process pressure at 400 °C
depends on process connection
Meest gedownload
Device viewer
Technical documentation in other languages
Taal:
Engels
Versie:
14/07/2021
Bestandsgrootte:
478.5 KB
Bestandsnaam:
SD02429R09EN_0121.pdf
Product family: Accessories: Pipe thermowell, Process RTD hygienic
Product root: TK40-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TT411-, TT412-
Declaration number: FDA_00127_03.24
Taal:
Engels
Versie:
20/07/2020
Bestandsgrootte:
423.6 KB
Bestandsnaam:
FDA_00127_03.24.pdf
14 documenten
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN
NL
Duits Spaans French Italiaans Japans Pools Portugees Russisch Chinees
25/03/2024
15/09/2023
28/10/2021
30/07/2021
19/06/2020
Taal:
Engels
Versie:
25/03/2024
Bestandsgrootte:
1.1 MB
Bestandsnaam:
TI00426FEN_2524.pdf
Thermometer thermowell for hygienic and aseptic applications
EN
NL
Duits Spaans French Italiaans Japans Portugees Russisch Chinees
29/07/2022
13/01/2021
31/10/2018
04/08/2017
Taal:
Engels
Versie:
29/07/2022
Bestandsgrootte:
1.2 MB
Bestandsnaam:
TI01350TEN_0422-00.pdf
Technical documentation in other languages
Taal:
Engels
Versie:
14/07/2021
Bestandsgrootte:
478.5 KB
Bestandsnaam:
SD02429R09EN_0121.pdf
SD Hygienic process connection types
Supplement to TM311, TM371, TM372, TM401, TM411, TM402, TM412, TT411, TT412, TE411, TK40, TMR35, DTT35, TTR35
Taal:
Engels
Versie:
15/09/2023
Bestandsgrootte:
800.3 KB
Bestandsnaam:
SD03119TEN_0123-00.pdf
Product family: Accessories: Pipe thermowell, Accessories: Inserts,
PROCESS RTD HYGIENIC, RTD thermometer
Product root: TK40-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, TS111-, TS212-, TT411-, TT412- Declaration number: HE_00886_01.17 Additional information: TSE compliance, animal fat free
Taal:
Engels
Versie:
23/10/2017
Bestandsgrootte:
160.7 KB
Bestandsnaam:
HE_00886_0117.pdf
Product family: Accessories: Pipe thermowell, Magphant, Process RTD hygienic, RTD thermometer
Product root: DTT35-, TK40-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, TT411-, TT412-, TTR35- Declaration number: HE_01097_03.24 Manufacturer specification: Food hygiene
Taal:
Engels
Versie:
24/10/2024
Bestandsgrootte:
112.3 KB
Bestandsnaam:
HE_01097_03.24_en.pdf
Product family: Accessories: Pipe thermowell, Magphant, Process RTD hygienic, RTD thermometer
Product root: DTT35-, TK40-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, TT411-, TT412-, TTR35- Declaration number: HE_00099_05.15 Manufacturer specification: Food hygiene, 10/2011, 1935/2004
Taal:
Engels
Versie:
07/12/2020
Bestandsgrootte:
1.7 MB
Bestandsnaam:
HE_00099_05.15.pdf
Product family: Accessories: Bar stock thermowell, Accessories: Pipe thermowell, Accessories: Inserts, Magphant, Process RTD general
purpose, Process RTD hygienic, RTD thermometer
Product root: DTT31-, DTT35-, TK40-, TM101-, TM111-, TM121-, TM131-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, TS111-, TS212-, TT131-, TT151-, TT411-, TT412- Declaration number: HE_01494_01.21 Manufacturer specification: Food hygiene Additional information: BSE, TSE
Taal:
Engels
Versie:
27/07/2023
Bestandsgrootte:
266 KB
Bestandsnaam:
HE_00886_07_17.pdf
Product family: Process RTD hygienic
Product root: TK40-, TM401-, TM402-, TM411-, TM412-, TS111-, TS112-, TT411-, TT412- Declaration number: MD-12028A-9
Taal:
Engels
Versie:
10/01/2013
Bestandsgrootte:
872.7 KB
Bestandsnaam:
MD-12028a_09_e.pdf
Product family: Accessories: Pipe thermowell, Process RTD hygienic
Product root: TK40-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TT411-, TT412- Declaration number: FDA_00127_03.24
Taal:
Engels
Versie:
20/07/2020
Bestandsgrootte:
423.6 KB
Bestandsnaam:
FDA_00127_03.24.pdf
60 spare parts & accessories
60 spare parts & accessories
60 spare parts & accessories
The unit is not repairable
Wij letten op uw privacy
We maken gebruik van cookies om uw browse-ervaring te verbeteren, statistische gegevens te verzamelen om de site-functionaliteit te optimaliseren en om reclame of content op maat te presenteren.
Door "Accepteer alles" te selecteren gaat u akkoord met ons gebruik van cookies.
Bekijk voor meer details onze cookie-richtlijnen .
Aanpassen
Alleen het essentiële accepteren
Accepteer alles