Zoek op trefwoord, order- of productcode of serienummer, bv. “CM442” of “Technische informatie”
Voer tenminste 2 karakters in om het zoeken te starten.
  • Geschiedenis
Bronhouder FQG63 - radiometrische metingen

Radiometrische
interfacemeting
bronhouder FQG63

Lichtgewicht stralingsbronhouder met flexibel verlengelement

FQG63
Please Wait (spinning wheel)
Prijzen worden geladen
Prijzen tijdelijk niet beschikbaar
Price on request
Bezig met activeren van prijs
Prijs: Informatie verstrekken
from CHF ??.-
Filter meting-/ toepassingstaak
Meet-/toepassingstaak

Configureer om de CAD-tekeningen van dit product te downloaden

  • Meetprincipe

    Radiometric

  • Characteristic / Application

    Source container with flexible extension element to position the source inside the process vessel (diptube)
    Approximately 87kg
    Adapter flange: 10kg

  • Specialities

    With flexible extension element

  • Ambient temperature

    -52 °C...+200 °C
    (-61 °F...+392 °F)

  • Process temperature

    max. 400°C (752°F)

  • Process pressure / max. overpressure limit

    Any (diptube)

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Meetprincipe

    Radiometric

  • Characteristic / Application

    Source container with flexible extension element to position the source inside the process vessel (diptube)
    Approximately 87kg
    Adapter flange: 10kg

  • Specialities

    Control area calculation with Applicator

  • Ambient temperature

    -52 °C...+200 °C
    (-61 °F...+392 °F)

  • Process temperature

    max. 400°C (752°F)

  • Process pressure / max. overpressure limit

    Any (diptube)

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Meetprincipe

    Radiometric Limit

  • Characteristic / Application

    Source container with flexible extension element to position the source inside the process vessel (diptube)
    Approximately 87kg
    Adapter flange: 10kg

  • Specialities

    Control area calculation with Applicator

  • Ambient temperature

    -52 °C...+200 °C
    (-61 °F...+392 °F)

  • Process temperature

    max. 400°C (752°F) (diptube)

  • Process pressure / max. overpressure limit

    Any (diptube)

  • Main wetted parts

    Non- contact

  • Process connection

    Non- contact

  • Meetprincipe

    Radiometric Limit

  • Characteristic / Application

    Source container with flexible extension element to position the source inside the process vessel (diptube)
    Approximately 87kg
    Adapter flange: 10kg

  • Specialities

    Control area calculation with Applicator

  • Ambient temperature

    -52 °C...+200 °C
    (-61 °F...+392 °F)

  • Process temperature

    max. 400°C (752°F)
    (diptube)

  • Process pressure / max. overpressure limit

    Any (diptube)

  • Main wetted parts

    Non- contact

  • Process connection

    Non- contact

  • Process connection hygienic

    Non- contact

  • Meetprincipe

    Radiometric Density

  • Characteristic / Application

    Source container with flexible extension element to position the source inside the process vessel (diptube)
    Approximately 87 kg
    Adapter flange: 10 kg

  • Ambient temperature

    -52 °C...+200 °C
    (-61 °F...+392 °F)

  • Process temperature

    max. 400°C (752°F) (diptube)

  • Process pressure

    Any

  • Wetted parts

    Non-contact

  • Hygienic

    Non-contact

  • Specialities

    Control area calculation with Applicator