Zoek op trefwoord, order- of productcode of serienummer, bv. “CM442” of “Technische informatie”
Voer tenminste 2 karakters in om het zoeken te starten.
  • Geschiedenis
Micropilot FMR60

Radarsensor
Micropilot FMR60

De standaardsensor voor het meten van vloeistofniveaus met 80GHz-technologie

FMR60
Please Wait (spinning wheel)
Prijzen worden geladen
Prijzen tijdelijk niet beschikbaar
Price on request
Bezig met activeren van prijs
Prijs: Informatie verstrekken
from CHF ??.-
Filter meting-/ toepassingstaak
Meet-/toepassingstaak

Configureer om de CAD-tekeningen van dit product te downloaden

  • Meetprincipe

    Level radar

  • Characteristic / Application

    For basic level measurement in liquids, pastes and slurries;
    non affected by changing media, temperature changes, gas blankets or vapor;
    For applications with many obstacles due to the very small beam angle.

  • Specialities

    Heartbeat Technology,
    SIL 2/3 according to IEC 61508,
    Bluetooth® commissioning,
    Operation and maintenance SmartBlue App,
    Safety and reliability with Multi-Echo Tracking
    HistoROM
    RFID TAG for easy identification

  • Supply / Communication

    2-wire (HART)
    Bluetooth® wireless technology and App (optional)

  • Frequency

    W-band (~80 GHz)

  • Accuracy

    +/- 1 mm (0.04 in)

  • Ambient temperature

    -40…+80 °C
    (-40…+176 °F)

  • Process temperature

    -40…+130 °C
    (-40…+266 °F)

  • Process pressure / max. overpressure limit

    Vacuum …16 bar
    (Vacuum … 232 psi)

  • Main wetted parts

    PTFE antenna
    PP or 316L process connections

  • Process connection

    Thread:
    G1-1/2", MNPT1-1/2";
    Flange:
    UNI DN80…DN150 (3"…6")

  • Max. meetafstand

    50 m (164 ft)

  • Communication

    4…20 mA HART,
    Additional switch,
    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, KC, EAC, UK Ex

  • Safety approvals

    Overfill protection WHG
    SIL 2, SIL 3

  • Design approvals

    EN 10204-3.1

  • Options

    Display,
    Customized parameterization,
    Remote operation via SmartBlue App using Bluetooth®,
    Gas-tight feed through,
    PWIS free

  • Application limits

    Process temp. > 130 °C (266 °F) -> FMR62
    Very aggressive media -> FMR62
    Strong turbulences and foam, stilling well and bypass -> FMR5x, FMP5x