Zoek op trefwoord, order- of productcode of serienummer, bv. “CM442” of “Technische informatie”
Voer tenminste 2 karakters in om het zoeken te starten.
  • Geschiedenis
Electromagnetic flowmeter - Proline Promag 53P

Promag 53P

53P
Please Wait (spinning wheel)
Prijzen worden geladen
Prijzen tijdelijk niet beschikbaar
Price on request
Bezig met activeren van prijs
Prijs: Informatie verstrekken
from CHF ??.-
Filter meting-/ toepassingstaak
Meet-/toepassingstaak

Configureer om de CAD-tekeningen van dit product te downloaden

  • Meetprincipe

    Electromagnetic

  • Product headline

    std_productprofile_product_usp_34659_1508940719.
    Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.

  • Sensor features

    Diverse applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
    Nominal diameter: max. DN 600 (24"). All common Ex approvals. Liner made of PTFE or PFA.

  • Transmitter features

    std_productprofile_product_benefits_34656_1508940491. std_productprofile_product_benefits_34658_1508940614. std_productprofile_product_benefits_34657_1508940613.
    std_successorproducts_product_differentiating_tech_features_35324_1509527963. std_successorproducts_product_differentiating_tech_features_35325_1509527962. std_successorproducts_product_differentiating_tech_features_35326_1509527956.

  • Nominal diameter range

    DN 15...600
    1/2"...24"

  • Max. meetfout

    ±0.2%

  • Measuring range

    0...9'600 m3/h

  • Max. process pressure

    PN10...40
    Cl 150...300
    JIS 10...20K
    AS 2129 Table E
    AS 4087 PN16

  • Medium temperature range

    -40...+180°C
    (-40...+356°F)

  • Ambient temperature range

    -20...+60°C
    -40...+60°C (optional)

  • Degree of protection

    IP 67 (NEMA 4x)
    IP 68 (Nema 6P)

  • Display/Operation

    Four line display with backlit
    Touch control

  • Outputs

    4...20 mA
    Pulse / frequenz (aktive/passive)
    Relays
    Status

  • Inputs

    Status
    Current input

  • Digital communication

    HART
    PROFIBUS PA
    Profibus DP
    FOUNDATION Fieldbus

  • Hazardous area approvals

    ATEX, FM, CSA

  • Product safety

    CE, C-tick, EAC marking