Product picture of: Deltapilot S DB51

Deltapilot S DB51

DB51
Please Wait (spinning wheel)
Prijzen worden geladen
Prijzen tijdelijk niet beschikbaar
Price on request
Bezig met activeren van prijs
Prijs: Informatie verstrekken
from CHF ??.-
Filter meting-/ toepassingstaak
Meet-/toepassingstaak
  • Characteristic / Application

    Pressure transmitter, for hydrostatic level measurement, flush mounted CONTITE-sensor with metallic measuring diaphragm Alloy C276 hermetically welded + safe humidity protection
    Rod version

  • Specialities

    full modularity

  • Supply / Communication

    3-wire analogue:
    15...20V DC
    4...20mA HART:
    11,5...30V DC
    PROFIBUS PA:
    9...24V DC
    Ex ia: 9...32V DC
    FOUNDATION Fieldbus:
    9...32V DC

  • Accuracy

    0,2%
    optional 0,1%

  • Long term stability

    0,1% of URL/6 months

  • Ambient temperature

    -40°C...85°C
    (-40°F...185°F)

  • Process temperature

    -10°C...80°C
    (-40°F...176°F)

  • Process pressure / max. overpressure limit

    25bar (375 psi)

  • Pressure measuring range

    100mbar...10bar
    (1.5 psi...150 psi)

  • Main wetted parts

    Alloy C276
    316L

  • Process connection

    Threads
    Flanges (DIN, ASME, JIS)

  • Max. meetafstand

    100m (328 ft) H2O

  • Communication

    3-wire analogue
    4...20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX
    CSA
    WHG/overspill protection

  • Options

    digital display
    SS-, Aluminium- or Polyesterhousing

  • Application limits

    Measuring cell: Contite,
    condensate-proof, watertight,
    metal welded
    If pressurized, possibly use
    differential pressure measurement
    In case of an open tank or shaft use DB53 with mounting clamp.
    with two pressure
    transmitters (electronic dp).
    Observe ratio head pressure :
    hydrostatic pressure